CMS-NC Bolt Load Cell

The next CMS evolution - now with a detachable cable

CMS-NC Bolt Load Cell

Official product page
The CMS-NC (Continuous Monitoring System, No Cable) gives you the best of both worlds: the security of accurate, on-demand bolt load measurement, with the option to disconnect the cable when a permanent connection isn't practical or safe.

Key Features

Detachable cableDisconnect the cable when a permanent connection isn't an option - e.g. when there's a risk of cable damage, or no room for an IoT Node - then reconnect any time for an instant reading.
View historical dataCheck the bolt load at any given moment and look back at historical readings to determine when and where a problem may have occurred.
Link multiple CMS-NC sensorsInterconnect several CMS-NC load cells within a network, so data from all sensors can be monitored from one connection point.
Check live data remotelyRead out live bolt load data remotely using any of six compatible BoltSafe readout methods.

Applications

Power Generation
Wind Industry
Petrochemical Industry
Mining
Civil Engineering
Mechanical Engineering

Readout Options

Single Reader

Quick on-the-spot readout via cable

Multi Reader

Connect up to 256 sensors to a single Multi Reader and view real-time data on the integrated display.

Converter

Converts BoltSafe data to analog outputs for one sensor at a time; includes a relay for alarm signalling.

Junction Box

Connects up to 8 CMS sensors per box directly to a PLC, DAQ, laptop or tablet via Modbus RTU/RS-485. Multiple boxes can be linked.

IoT Node

Wireless LoRaWAN® readout to a cloud server; one IoT Node per sensor.

Bluetooth Node

Bluetooth 5.2 Low Energy, real-time plotting of up to 4 Bluetooth Nodes at once.

Technical specifications

SizesTo fit bolt sizes from M12 to M100 (7/8″ to 4″)
Cable lengthStandard 1 m (5 or 10 m optional)
Full Scale Load (FS)From 6 kN to 4,040 kN, depending on sensor size
Maximum Load at ambient temperatureFS range × 1.3
Temperature range-40°C to 80°C
Storage temperature-40°C to 80°C
Minimum load10% FS
Total accuracy at ambient temperature (rms)<1% FS
Linearity<1.5% FS
Hysteresis<0.9% FS
Creep<0.1% FS
Repeatability<0.5% FS
Typical temperature effects<±0.08% FS/°C
SealingIP66
MaterialStainless Steel 17-4 PH, Condition H1025
Sensor outputSerial digital signal
Power supplyPowered through electronic interface
ConnectionM12 connector male, 5-pole
M12 connector male, 5-poleII 2 G, EEx ib IIC T4 (on special request)
High-load variant+15% higher max. load rating available, same dimensions - contact us
PatentPatented technology - EP 1 412 708 B1 (published as WO 2003/006942 A1)